Robust Details Floor Build Up
The robustdetails scheme does not apply to internal floors in houses.
Robust details floor build up. Sign in sign up to download the online handbook robustdetails is the alternative to pre completion sound testing in new attached dwellings under the authority of statutory instruments 2004 1465 1466. E fc 16 precast concrete plank with direct applied screed and thermal economics cc3 bonded resilient floor covering e fc 17 concrete precast plank cellecta yelofon hd10 floating screed and cellecta ultra ceiling treatment. Robust details were set up in 2004 to help architects and building contractors design and construct separating elements with confidence. Robust detail fft 4 resilient overlay platform floor systems can be used in e fc 1 e fc 2 e fc 7 e fs 1 separating floors.
In timber separating floors such as robust detail e ft 1 e ft 2 e ft 3 a 25mm mineral wool and a layer of gypsum based board with a nominal mass of 13 5kg m is installed on top of battens prior to the 18mm min tongued and grooved board. When using robust details walls and floors in flats details from the same construction group should be selected. Refer to the relevant combination table to ensure compatibility. Solid external masonry wall.
By continuing to browse our website or by closing this message you accept our use of cookies. Robust details is the market leader in sound testing compliance for part e building regulations the robust details website uses cookies to give you the best possible experience on our website. 150mm insulation 0 044w mk between rafters. They meet all other requirements of the robust detail including flanking constructions.
The mass of the proprietary platform system inclusive of resilient layer greater than or equal to 16 kg m2 mass per unit area. The acoustic floor slab must achieve a minimum laboratory performance of rd lw 17db. The principles of the raft foundation junction are followed. 215mm aircrete solid wall λ 0 15 w mk render insulation λ 0 022 w mk pitched roof gable.
The guidelines set out within robust details provide separating floors walls that are capable of achieving the sound performance parameters in approved document e whilst complying with building regulations. Robust detail floor system selection scotland only in order for separating elements to avoid the requirement for pre completion acoustic testing plots must be registered with robust details ltd rdl and that construction must be strictly in accordance with the relevant requirements of the robust details part e handbook.