Reinforced Concrete Floor Slab Section Detail
Slab supported on two sides and bending takes place predominantly in one direction only is called one way slab.
Reinforced concrete floor slab section detail. The slab is constructed on well compacted granular fill crushed stone or marl. The mesh reinforcement in the slab is placed in the top with 1 covers. The top steel reinforcement is important. If reinforcement is correctly designed and placed and if the concrete is placed and compacted well so there are no voids or porous areas concrete slabs can have an almost unlimited life span.
Reinforcement detailing of a slab is done based on its support conditions. Steel decking concrete floor detail cad dwg drawing for a steel decking concrete floor detail. Top of reinforced concrete wall retaining basement wall connection to flat slab two way slab cast in place concrete floor cast in situ rc slab. Includes detail of concrete wall corner reinforcement.
Ground bearing floors shall be of adequate strength and durability and use concrete mixed and reinforced as necessary to support floor loads safely and resist chemical and frost action. Slab may be supported on walls or beams or columns. The reinforced concrete waffle slab ribbed slab cross section reinforcement detail includes ribbing beams reinforcement slab top wire mesh waffles dimensioning voids width and depth slab thickness. Reinforced concrete stairs cross section reinforcement detail.
Reinforced concrete beam column end support detail floor slabs detallesconstructivos what is meant by monolithic slabs and beams quora the connection between interior. The suspended reinforced concrete slab is tied into the external capping beam at floor level. Long life concrete s high embodied energy can be offset by its permanence. Floor slab connection main top and bottom reinforcement middle landing support and transverse reinforcement.
This article is the first in a series on recommended reinforcement details for cast in place concrete construction. Slab supported directly by columns are called flat slab. In two way construction load transfer is by bending in two directions. Drawing detail includes minimum slab anti crack reinforcement minimum cover low carbon shear studs welded on top of steel ipe floor beam and galvanized steel decking profile section description.
Ground bearing concrete floor slabs should be at least 100mm thick including monolithic screed where appropriate. Concrete staircases with landing. Alternative floor slab detail. Two way slabs are generally defined as suspended slabs where the ratio of the long to the short side of a slab panel is 2 or less.