Raised Floor For Server Room Specifications
If you are unfamiliar with the the terms used to describe the loads on raised floor a quick visit to understanding loads will assist you.
Raised floor for server room specifications. 200 500 square meters about 400 mm. The raised floor is constructed of 600x600mm anti static floor tiles to the information room with a height of at least 300mm. Category 6 cable commonly referred to as cat 6 is a cable standard for gigabit ethernet and other network protocols that feature more stringent specifications for crosstalk and system noise. For computer room raised access floors and or non ground floor basement areas it is important to check the floor loading to ensure the the floor structure can support the weight of the server rack or ups system to be placed upon it.
To put it simply an access raised flooring system is elevated flooring in your business an area upon another floor typically a concrete slab in a building. Access floor systems inc. Newly added to the information center are the ada codes for computer floors. These definitions apply to these terms as they are used in this document.
Computer and server rooms require raised flooring that has different properties to that of a standard office raised flooring system. Data centers and server rooms without raised floors are perceived as being incomplete or less than state of the art. Server room partitioning doors visual glass windows 2 hour fire rated 8. Metal perforated false ceiling with suitable assembly.
Required raised floor height for data center. Normally access floors are used as part of the computer room flooring design in order to provide space for the large amount of wires and cables that exist without affecting the work. Computer room air conditioner data center. This is an informal opinion about our interpretation of the ada requirements for access to raised floor environments.
When used as an exhaust space refer to vdi 2054 for the floor room air conditioning system standard for floor height. 203 north columbia street covington la. Structured cable tray arrangement in all areas 10. Computer access flooring server rooms data centers.
Server room raised floors are the hallmark of the high availability enterprise data center and with good reason. What s more computer room raised floors to. Thermal insulation of the server room floor. The system will be similar to a standard raised flooring in that the server room floor tiles panels will be 600mm x 600mm and supported on pedestals but the system will also incorporate the additional.
Raised flooring with suitable pedestal assembly. A large facility designed to support large numbers of servers in a large. Floor loadings are measured in kn m. A three phase 100kva ups with a 5m battery can have a total weight of 1200kg or 1 2tonnes.