Psa Raised Floor Specification
Psa mob pf2 ps spu key performance mob pf2 ps spu specification.
Psa raised floor specification. Rmg600 systems are one of our most commonly specified raised access flooring solutions. The mob standard was set up by the public services agency and was compiled in 1992 and became the definitive raised flooring standard. The bsen standard was. Specification guide definitions.
We are sgs btl cisca certified psa mob pf2 ps spu compliant and a proud member of riba. All the testing procedures are based on psa mob pf2 ps spu specification. Current specifications european raised flooring systems now fall into two main specification categories. Those being psa mob pf2 ps and the new european and uk british standard bsen 12825 2001.
The property services agency psa method of building performance specification platform floors raised access floors mob pf2 ps became the industry standard in the uk and has been for around 20 years until the recent arrival of the bs en 12825 2001 specification. Fdeb h is a raised access floor system intended for offices containing heavy equipment fdeb h is our heavy grade system capable of handling a 12kn m2 uniformly distributed load. Devar group provides integrated solutions of raised access flooring premium floor finishes and wall partitions for office public government and industrial complexes in united kingdom china macau singapore qatar and uae. Access flooring is a division of raised floor solutions ltd and an approved designer supplier and installer of kingspan access floor.
Specification guide definitions psa v bsen specification guide. The en 12825 standard was designed to allow all. In order to assist specifiers in determining the actual performance specification that is appropriate the access flooring association afa has issued a specification guide which attempts to show a comparison between the psa bsen12825. Fdeb h is suitable for data centre and server room use with heavy equipment.
Access floors have become an integral part of the flexible modern office environment accommodating a heavy reliance on technology through the concealment of data telecommunication and power sources and allowing the refurbishment or reconfiguration of spaces. The mob standard was set up by the public services agency and was compiled in 1992 and became the definitive raised flooring standard. Those being psa mob pf2 ps spu and the new european standard en 12825 2001. An rmg600 flooring solutions is particularly suitable for general office environments where there are significant levels of building services in the floor void including electrical power data telecoms air conditioning or environmental control security fire detection and suppression.
Welcome here to check out the true load performance specification concentrated loads roll loads design loads ultimate loads impact loads safely factor of huiya raised access floor systems which will help you quickly and easily determine the type of access floor system most suited to your individual requirements.