Protective Device Required In A Floor Opening 12
Such as a belt hole pipe opening or slot opening.
Protective device required in a floor opening 12. Osha continues to state in standard 1910 23 a 5. A 1 every floor and roof opening shall be guarded by a cover a guardrail or equivalent on all open sides. A passageway for persons elevated above the surrounding floor or ground level such as a footwalk along shafting or a walkway between buildings. Every pit and trapdoor floor opening infrequently used shall be guarded by a floor opening cover of standard strength and construction.
Skylight screen fixed standard railing. Inside protective cover when opening and closeing wires will get brittle wiht age and crack or just could be the relay. Hoist area means any elevated access opening to a walking working surface through which equipment or materials are loaded or received. When using a powered scissor lift in an elevated position is it legally required to use fall protection devices i e belt or harness with attached safety line.
Hole means a gap or open space in a floor roof horizontal walking working surface or similar surface that is at least 2 inches 5 cm in its least dimension. Toeboards shall be installed around the edges at openings where persons may pass below the opening. An opening measuring 12 inches or more in its least dimension in any floor platform. While the cover is not in place the openings shall be constantly attended by someone or shall be protected by guardrails.
Floor openings occupied by elevators dumb waiters conveyors machinery or containers are excluded from this standard. The floor covering should overlap the surrounding structure by 12 inches. An opening measuring 12 inches or more in its least dimension in any floor platform pavement or yard through which persons may fall such as a hatchway stair or ladder opening pit or large manhole. Every skylight floor opening and hole shall be guarded by a standard or a on all exposed sides.
When working on a job site with floor coverings and floor openings workers should mind their steps and the floor surfaces their feet will touch. Electrical protective devices shut off electrical flow in the event of an overload or. Section 4 12 2 of the subject ansi sia standard requires that platforms have guardrail systems and sets criteria for those systems. While the cover is not in place the pit or trap opening shall be constantly attended by someone or shall be protected on all exposed sides by removable.
An opening measuring less than 12 inches but more than 1 inch in its least dimension in any floor platform pavement or yard through which materials but not persons may fall. It should have a sign that says opening do not remove in 2 inch high black bold letters on a yellow background.